Testing / 01

Water Test

Every idler and pulley is subjected to sustained water exposure to verify seal integrity and confirm the bearing region resists moisture penetration under real-world operating conditions.
Applied pressure

Applied pressure

minimum
Test Duration

30 Minutes or More

maximum
Bearing Inspection

Water Penetration Check

minimum

Procedure

How the water test is performed

Mount the assembly

The fully assembled pulley is fixed to the test rig in its standard operating orientation.

Apply Water Spray

Controlled water spray is applied to the roller and bearing areas using multiple spray nozzles.

Run the Test

The roller is rotated continuously under controlled operating conditions while water exposure is maintained.

Inspect & Verify

The assembly is inspected for water ingress, seal integrity, and bearing protection after testing.

Related quality checks

Dust Test

Our rollers undergo controlled dust exposure to evaluate sealing performance and prevent dust penetration into critical bearing areas.

Friction Test

Friction testing evaluates roller performance under continuous load, ensuring smooth rotation, durability, and reduced resistance during operation.

Become A Zero-Defect Quality Assurance